Adder Technology SV16PRO Network Card User Manual


 
SmartView Installation and Use Page 36
4.9 Cascade query code
The SmartViews use a special ‘query code’ to detect whether or not they are
connected to another SmartView. By default your SmartView Pro uses query code
AD. SmartView Pro units with firmware versions less than 1.09 and SmartView units
with firmware version less than 1.18 used query code EF. This was found to conflict
with a small number of other (rare) devices that used the same query code so an
alternative query code was provided to ensure compatibility. Either query code may
be used but you should make sure that all cascaded SmartView units are set to use
the same query code. If any of the cascaded SmartView Pros have firmware
versions less than 1.09 then the cascade query code for all the SmartView Pros
should be set to EF.
L7 – Cascade query code = AD (default)
L8 – Cascade query code = EF
4.10 Exit configure mode
When you have finished configuring any special options, simply type ‘E’ followed by
(enter) to exit configure mode and return to normal operation mode. The attached
computers can now be switched on.