9. Change the emulation software properties to 9600 baud. Disconnect and connect to the
unit at this transmit rate and continue configuring the unit as normal.
Updating Firmware via the Console Menus
1. Using a VT 100 terminal emulation communication software package which contains XMO-
DEM protocol support, log in to TA 600.
2. Select 6
<67(0
8
7,/,7<
/8
3'$7(
)
,50:$5(
.
3. Select ;02'(0 for 7
5$16)(5
0
(7+2'
.
4. Press
(QWHU
on 6
7$57
7
5$16)(5
!
5. When prompted, press
<
to erase flash.
6. From the terminal emulation software, begin the XMODEM upload by using the appropriate
command sequence. (If necessary, refer to terminal emulation software documentation for
help. Also, when specifying the filename, ensure that the file transferred is the one pro-
vided by ADTRAN. Otherwise, the update will not complete successfully.)
7. When the update has successfully completed, 7
5$16)(5
&
203/(7(
displays in 7
5$16)(5
6
7$786
. The module restarts immediately and resumes operation. If an error occurs during
the update, an error message will display in the 7
5$16)(5
6
7$786
field. If this occurs, return
to Step 3 and attempt the update again. If the same error occurs, contact ADTRAN Techni-
cal Support.
It is suggested that a factory default be conducted after the unit is updated with new firmware.
When Total Access 600 is ready to receive the XMODEM upload, the menu screen will clear and
display
7UDQVPLW)ODVKGRZQORDGILOHQRZ
. If this does not appear, please review the steps
above for possible configuration errors.
Because XMODEM data is being transferred in-band through the menu interface, the VT 100
menus of Total Access 600 will be inoperable from the
&5$)7
port.