Option Modules NetVanta 1000/1000R Series Hardware Installation Guide
36 Copyright © 2008 ADTRAN, Inc. 61200500L1-34N
Network Interface Modules
NetVanta 56K/64K NIM (P/N 1200861L1)
The 56K/64K NIM (shown in Figure 23) provides a DDS WAN interface for the NetVanta. This module
provides a single 56K or 64K DDS network interface. See Table A-5 on page 69 for the WAN-DDS connector
pinouts, and page 73 for the DBU connector pinouts. An optional DIM is required for dial backup applications.
Figure 23. NetVanta 56K/64K NIM
Features and Specifications
Operating Modes
• Dedicated DDS (leased line)
DDS Interface
• Supported Standards: AT&T TR 62310
• 4-wire, full-duplex
• Receiver Sensitivity: -45 dB, all rates
• Data Rates: 56K, 64K, and auto
• Connector: RJ-48S
Clock Source
•Network
•Internal
Diagnostics
• CSU and DSU Loopbacks
Compliance
• EMC - see Electromagnetic Compatibility
(EMC) Table on page 6.
• ACTA/FCC Part 68
• IC CS-03
• UL/CUL 60950
Environmental
• Operating Temperature: 0°C to 50°C
• Storage Temperature: -20°C to 70°C
• Relative Humidity: Up to 95 percent,
noncondensing
Physical
• Dimensions: 2.75-inch W x 4.25-inch D