ADTRAN L768 Network Router User Manual


 
Appendix E: Terminal Mode Commands
61202192L1-1 Express L768/L1.5 User Manual 107
Additional Commands
Other commands available from the terminal mode are given below:
Download/Uploading Configuration
The Express L768/L1.5’s configuration can be captured to a text file using the
download command. The text file can be edited if required. Upload of the
configuration can be accomplished by sending the text file to the Express
L768/L1.5 in terminal mode. A baud rate of 9600 is strongly recommended
when uploading. As soon as the upload has been completed, type “save” to
save the new configuration to flash. A “reset” command or power cycle 10 sec-
onds after the save command is recommended to ensure that the new config-
uration is complete.
save Saves the configuration to non-volatile RAM (flash).
mac Returns the MAC address for the Express L768/L1.5.
version Returns the firmware version and routing stack version.
reset Resets the unit.
exit Leaves terminal mode and returns to menus.
download Downloads complete configuration to the terminal screen for
capture.