ADTRAN QFO-C Network Card User Manual


 
Menu Descriptions
61181500L2-5B 19
Provisioning Menu
The Provisioning menu (see Figure 8) is used to set the service state.
Figure 8. Provisioning Menu
The Provisioning menu options are shown in Table 10.
Table 10. Provisioning Menu Options
Option Description Function
1 Service State This option indicates the service state of the LPU.
The following service states are available:
In Service: Power supply output is turned on, and
all alarms are reported.
Out of Service-Maintenance: Power Supply
output is turned on, alarms reported at LPU only,
alarm reporting to the
Controller Unit is
suppressed.
Out of Service-Unassigned: Power Supply output
is turned off, and all alarms are suppressed
(default).
2 Reset Defaults This option is used to reset the LPU to factory
defaults.
Shelf: 1 Slot: 4 Total Access System MM/DD/YY HH:MM
Unacknowledged Alarms: NONE
Provisioning
Unit Name : Line Powering Unit
1. Service State : IN SERVICE
2. Reset Defaults
Selection:
? = Help ESC = Exit Menu