ADTRAN QFO-C Network Card User Manual


 
General
61181500L2-5B 3
Compliance
WARNING
The span voltages are up to ±145 VDC with respect to ground and
up to 290 VDC between the tip/ring pairs.
CAUTION
Electrostatic Discharge (ESD) can damage electronic modules.
When handling modules, wear an antistatic discharge wrist strap
to prevent damage to electronic components. Place modules in
antistatic packing material when transporting or storing. When
working on modules, always place them on an approved antistatic
mat that is electrically grounded.
Table 1 lists the compliance codes for the LPU. The LPU is NRTL Listed to the applicable UL
standards. The LPU meets or exceeds all the applicable requirements of NEBS, Telcordia GR-
63-CORE, and GR-1089-CORE.
The LPU is intended for deployment in Central Office type facilities, EEEs and EECs. Install
the LPU in a Total Access 3000/3010 Chassis located in a restricted access location.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority
to operate this equipment.
Table 1. Compliance Codes
Configuration Code Input Output
Power Code (PC) F C
Telecommunication Code (TC) X
Installation Code (IC) A
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.