Advantech 4718 Computer Drive User Manual


 
27 Chapter 3
3.2.4 3.2.4 Jumper Setting Description
JP1~JP8: Input Mode Setting for Analog Input Channels
The analog input mode of every AI channel on USB-4718 can be set by
JP1~JP8 separately to measure the voltage sources or the current sources.
Inappropriate setting of the jumpers can cause unpredictable errors or
malfunction of USB-4718.
Table 3.3: Jumper Setting Description
Jumper Description Jumper Description
JP1
Input mode set-
ting for analog
input ch0
JP6
Input mode setting for analog
input ch6
JP2
Input mode set-
ting for analog
input ch4
JP7
Input mode setting for analog
input ch3
JP3
Input mode set-
ting for analog
input ch1
JP8
Input mode setting for analog
input ch7
JP4
Input mode set-
ting for analog
input ch5
JP13
Watchdog timer setting
JP5
Input mode set-
ting for analog
input ch2
Jumper
Setting
Description
Set the channel to voltage
input mode (Default setting)
Set the channel to
current input mode