AeroComm CL4490-1000 Network Card User Manual


 
CL4490 User’s Manual
4.2.1 CL4490 Settings
The CL4490 Settings Page is shown below, as it will appear the first time the
program is run.
4.2.1.1 ConnexLink Settings
Client/Server: Designates CL4490 type. In each network, there must be only one Server.
All other CL4490 units must be programmed as Clients. The number of Clients in the
network is not limited; however, if performance diminishes, consider additional RF Networks.
Interface Baud Rate: This defines the baud rate used for communicating with the CL4490
over the serial interface. The RF baud rate is fixed at 76.8 Kbps and is independent of the
Interface Baud Rate. The default baud rate setting is 57600 bps unless the units have been
pre-configured by AeroComm. The Interface Baud Rate setting of the CL4490 must
match the Baud Rate setting of its host device.
Channel
Number: A number that designates an independent network of CL4490 units. Up
to 32 independent networks can be created.
The valid range of values for this field is 16 to
47.
10/3/2005 16