MULTITASKER™
400-0197-005
14
14
Command Format: [ImO*CnUi]
m = Input (m = # from 1 to 8)
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Connect Input 1 to all outputs for the
MT110-103 in slot 5. Send the command
[I1O*C5] and Input 1 will be connected to all
outputs.
16. [CLR]
This command clears the card, restoring the
default settings. In this case, Input 1 to all
outputs, all outputs on and all input levels to
maximum.
Command Format: [CLRCnUi]
Cn = Group ID (n = # from max slots)
Ui = Unit ID (i = # from 0-9)
Example:
To clear the card in slot 4, send the [CLRC4]
command. The card in slot 4 is now set to its
default values.
17. [OSI]
This command sets the input offset value that is
applied to all inputs. The default is zero, or
Input 1 equals Input 1. An offset of 16 would
make Input 1 equal to Input 17.
Command Format: [OSImCi]
m = Offset (m = # from 0 to 128)
Ci = Card ID (i = # from 1 to max slots)
Example:
[OSI16C8] sets the input offset value to 16 for
the card in slot 8. The inputs on card 8 will now
be their physical number plus the offset value.
In this case, Input 1 would now be Input 17.
18. [OSO]
This command sets the output offset value that
is applied to all outputs. The default is zero, or
Output 1 equals Output 1. An offset of 16 would
make Output 1 equal to Output 17.
Command Format: [OSOmCi]
m = Offset (m = # from 0 to 128)
Ci = Card ID (i = # from 1 to max slots)
Example:
[OSO16C8] sets the output offset value to 16 for
the card in slot 8. The outputs on card 8 will now
be addressed by the value of their physical
number plus the offset value. In this case,
Output 1 would now be Output 17.
19. [FBD]
This command turns feedback delay on or off. It
is necessary when installing some newer cards
in older systems. If the system does not receive
all of the feedback from the card, the card may
be communicating too fast. This command will
slow down the card's communication rate.
Command Format: [FBDmCnUi]
m = Delay (0= no delay, 1= delay 100mS)
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = from 0 to 9)
Example:
The command [HELPC4] is sent to the card in
slot 4. Some of the HELP file is displayed on the
screen, but most is missing. Send the command
[FBD1C4] to slow down the rate at which the
card sends feedback to the system.