Altinex MT110-101 Switch User Manual


 
MULTITASKER
400-0197-005
19
19
34. [RUP] MT110-103 ONLY
This command ramps the output volume to its
maximum level at the rate defined using the
[RAMP] command.
Command Format: [RUPCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Ramp the output volume on Output 1 from a
starting level of 10 to the maximum level of 32
for the card in slot 8. Send the commands
[SEL1C8] then [RUPC8] and the system will
respond with the following feedback:
[11][12][13][14]…[32]
35. [RDN] MT110-103 ONLY
This command ramps the output volume down
to a level of 00 at a rate defined using the
[RAMP] command.
Command Format: [RDNCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Ramp the output volume on Output 1 from a
starting level of 32 down to 00 for the card in
slot 8. Send the commands [SEL1C8] then
[RDNC8] and the system will respond with the
following feedback:
[31][30][29]…[00]
36. [RUPm] MT110-103 ONLY
This command ramps UP the output volume for
the specified output on the card. The ramping
will continue to its maximum level at the rate
defined using the [RAMP] command. The
ramping may be stopped at any time using the
[RST] command.
Command Format: [RUPmCnUi]
Cn = Card ID (n = # from 1 to max slots)
m = Output No. (n = # from 1 to 8)
Ui = Unit ID (i = # from 0 to 9)
Example:
Ramp the output volume for Output 2 from a
starting level of 10 to the maximum level of 32
for the card in slot 8. Send the command
[RUP2C8] and the system will respond with the
following feedback:
[11][12][13][14]…[32]
37. [RUPm=xx] MT110-103 ONLY
This command ramps a specified output’s
volume to a user defined level at a rate defined
using the [RAMP] command.
Command Format: [RUPm=xxCnUi]
m = Output No. (m = # from 1-8)
xx = Stop Level (xx = # from 01-32)
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Ramp the output volume on output 7 from a
starting level of 1 to a level of 20 for the card in
slot 8. Send the command [RUP7=20C8] and
the system will respond with the following
feedback:
[02][03][04]…[20]
38. [RDNm] MT110-103 ONLY
This command ramps DOWN the output volume
for the specified output on the card. The
ramping will continue to its minimum level at the