7.4. SUMMARY OF COMMANDS
1) [STATUS] Display card status
2) [CLR] Reset card to defaults
3) [VER] Display firmware version
4) [ONmX] Turn ON single output
5) [ON] Turn ON all outputs
6) [OFFmX] Turn OFF single output
7) [OFF] Turn OFF all outputs
8) [InOmX] Connect to one output
9) [InO*] Connect to all outputs
10) [...P] Sets the path, [SW] preload
11) [SW] Switch preloaded outputs
12) [AUTO*] Auto-switch: ON, all outputs
13) [AUTO0] Auto-switch: OFF
14) [AUTO1] Auto-switch: ON, Out #1
15) [AUTO2] Auto-switch: ON, Out #2
16) [HELP] Display available commands
17) [?] Display system information
18) [STA1] Auto-feedback on
19) [STA0] Auto-feedback off
20) [...S] Save current setting
21) [AFB] Enable/disable “[ ]”
22) [SIDn] Set all Card IDs
23) [RSI] Reset Card IDs to defaults
TROUBLESHOOTING GUIDE 8
We have carefully tested and found no problems in
the supplied UT250-101; however, we would like to
offer suggestions for the following:
8.1 POWER LEDS ARE OFF
Cause 1: The unit is not plugged in.
Solution: Make sure the power adapter is
plugged into a working AC outlet
and that the adapter’s DC end is
plugged all the way into the
UT250-101. If both LEDs are still not
ON, see Cause 2.
Cause 2: The unit has a problem.
Solution: If one power LED is on, but the other
is not then the UT250-101 may have
a problem. Please call ALTINEX at
(714) 990-2300.
8.2 NO DISPLAY
Cause 1: The source has a problem.
Solution: Check the source and make sure
that there is a signal present and all
source connections are correct. If
the source is working and there is
still no display, see Cause 2.
Cause 2: The output is not selected.
Solution: Verify the connection status of the
UT250-101. (See RS-232 accessible
commands in Section 7.) If no
display is present, see Cause 3.
Cause 3: Cable connections are incorrect.
Solution: Make sure that cables are properly
connected. Also, make sure that the
continuity and wiring are good. If
there is still no display present, see
Cause 4.
Cause 4: The display has a problem.
Solution: Make sure the display is powered
and turned on. If there is still no
display, please call ALTINEX at
(714) 990-2300.