Connecting the UPS
18
NXA-UPS1500 Uninterruptible Power Supply
Connect Network Surge Protection
Connect a 10Base-T/100 Base-T network cable to the RJ45 network surge protection "IN" jack on the
rear of the UPS. Connect from the "OUT" jack with network equipment (FIG. 18).
Connect the RS-232 Communication Port
Connect the supplied RS-232 interface cable between the RS-232 port on the rear of the UPS and an
available RS-232 port on the NetLinx Master (FIG. 19).
FIG. 18 Connect Network Surge Protection
If using the NXA-UPS1500 as part of a MAX system, do not run the A/V segment of
the network through the RJ45 network surge protection jack on the UPS. The A/V
segment of a MAX network requires a GB Ethernet switch, and the NXA-UPS1500
only provides a 10/100 connection. You can connect the Control segment of the MAX
network to the UPS, since it does not require a GB connection to operate properly.
FIG. 19 Connect RS-232 Communication Port