APC UTS6H Power Supply User Manual


 
9 Operation Manual Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI
Generator Start Mode
For generators featuring manual start, use the MANUAL setting. Press the down or
up arrow key to change to AUTO setting.
A warning message appears on the LCD. Wait a few seconds and another message
appears on the LCD asking for confirmation that the generator is located outdoors.
Use the down or up arrow keys to select YES or NO.
A UTS Hardwire Interface Kit for connecting the generator outside the house is
available through your dealer or APC, www.apc.com.
WARNING: Home generator backup systems should be installed by a qualified electrician.
Locate the generator outside a building and at least 10 feet away from buildings, windows, and doors.
Failure to follow this safety rule may result in illness or death from breathing carbon monoxide.
The generator must have three to four feet of space around all sides and the top to ensure proper
ventilation.
Locate the generator on a dry, level surface protected from rain and excessive dust.
Fuel for gas operated generators must be stored in approved containers, and in well ventilated
conditions.
Refer to the generator user documentation for additional safety precautions.
For generators featuring automatic start, use the AUTO setting.
The UTS has a remote automatic start/stop function for use with generators having the following features:
automatic start
automatic choke
remote start/stop capability
Refer to the documentation in the Generator Automatic Start/Stop Kit for automatic generator configuration
instructions.
Backup2 Source Type
The factory default setting is UPS. The backup2 power source inlet, located on the
front of the UTS is labeled UPS Inlet as a UPS is the preferred backup2 power
source.
The system setup has three options for backup power:
• Generator
UPS (recommended BACKUP2 power source)
• Other
Use the down/up arrow keys to select the preferred backup power source.
NOTE: It is recommended that a UPS be used as BACKUP2 SOURCE TYPE. A UPS provides continuous
battery backup power during utility brownouts, sags, surges, and power outages.
Without the use of a UPS, fully automatic operation of the UTS cannot be guaranteed.
If a UPS is not selected for the BACKUP2 power source be sure that the UNINTERRUPTIBLE option under
Circuit Setup Option 2 is not selected.
GEN START MODE:
MANUAL
CONFIRM GEN OUTDOORS:
NO
GEN EXHAUST CAN KILL
START GEN OUTDOORS..
BACKUP2 SOURCE TYPE:
UPS