Aruba AP 60/61 19
Installation Guide
Provisioning Access Points
Chapter 2
where the following fields are required:
If you performed the recommended site survey using the Aruba RF Plan
tool, the location data for all access points and air monitors can be found
on the tool’s deployment page (see the ArubaOS User Guide).
If you prefer to enter the location data manually, record the location ID
you set for each access point and air monitor along with the following:
4. Save the configuration and reboot the Aruba AP 60/61.
Once the Aruba AP 60/61 boots, disconnect it and mount it in its intended service
location (see Provisioning Access Points on page 21).
Building Number A unique number (1-254) is required for each building in
your campus.
Floor Number Within any building, a unique number (1-254) is
required for each floor.
Device Number Within any floor, a unique number (1-65534) is required
for each access point or air monitor.
Device
Description
Note the intended function of the device (access point
or dedicated air monitor) and a brief description of its
service location.
X, Y
Coordinates
For each access point and air monitor, measure its X
and Y position (in feet) relative to the bottom-left corner
of the building plan as seen from overhead. For
example:
Use the same fixed point and orientation for all floors in
a building.
apboot> save
apboot> boot
0,0 126
98
X
418 ft.
Y
262 ft.