Output Voltage Regulation, Ripple, and Noise
Output Current Capacity
Input Voltage
Safety
The power system meets all applicable clauses for UL 1950 2nd edition with-
out D3 deviations. The power system passes all tests for CUL and TUV
safety.
EMI
The power system, operating with resistive load, meets FCC class B and
CISPR 22 class B conducted limits.
Power Supply Info
Output Voltage Limits (Vdc) Ripple/Noise
Output Min Nom Max Maximum
1 3.17V 3.30V 3.46V 50mV
p-p
2 4.80V 5.00V 5.25V 50mV
p-p
3 11.40V 12.00V 12.60V 120mV
p-p
4 -4.50V -5.00V -5.50V 120mV
p-p
5 -10.92V -12.00V -13.20V 120mV
p-p
6 4.75V 5.00V 5.25V 50mV
p-p
* Total output power for 3.3V and 5V combined shall be 210W
Power Supply Information
Output Nom (Vdc) Max (A) Min (A)
1 3.3V *20.0 1.0
2 5.0V *45.0 2.0
3 12.0V 12.0 0.5
4 -5.0V 0.5 0.0
5 -12.0V 0.5 0.0
Range Min (V) Nom (V) Max (V)
Range 1 90 120 137
Range 2 180 230 265