Asus P7F-C Computer Hardware User Manual


 
5-28 Chapter 5: RAID configuration
4. Use the arrow key to select the disk you would like to configure as hot spare,
then move the cursor to the Hot Spr column. Press <+>, <->, or <Space>.
The Drive Status column field now shows Hot Spare.
Press <C> to commit the changes.
Synchronizing the array
Synchronizing the array allows the utility to resynchronize data on the mirrored disk
in the array. This procedure is seldom required because data synchronization is
automatically done during normal operation.
To synchronize the array:
1. Follow steps 1 ~ 3 of the section
Viewing volume properties
and step 2 of
the section
Managing hot spares
.
2. From the
Manage Array
screen select
Synchronize Array
, then press
<Enter>.
3. Press <Y> to begin the synchronization, or <N> to cancel.
Esc = Exit Menu F1/Shift+1 = Help
SPACE/+/- = Change Item C = Commit Changes
LSI Logic Cong Utility v6.16.00.00 (2007.05.07)
Manage Hot Spare -- SAS1068E
Identier LSILOGICLogical Volume 3000
Type IME
Scan Order 0
Size(MB) 51498
Status Optimal
Slot Device Identier Hot Drive Pred Size
Num Spr Status Fail (MB)
0 SEAGATE ST373454SS 0003 [NO] Ok No 34331
1 SEAGATE ST373454SS 0003 [NO] Ok No 34331
2 SEAGATE ST373454SS 0003 [NO] Ok No 34331
3 SEAGATE ST373454SS 0003 [Yes] Hot Spare No 35003
[----] --------- -- -----
Esc = Exit Menu F1/Shift+1 = Help
Enter = Select Item
LSI Logic Cong Utility v6.16.00.00 (2007.05.07)
Manage Array -- SAS1068E
Identier LSILOGICLogical Volume 3000
Type IME
Scan Order 0
Size(MB) 51498
Status Optimal
Manage Hot Spare
Synnchronize Array
Activate Array
Delete Array