Asus P7F-C Computer Hardware User Manual


 
5-46 Chapter 5: RAID configuration
5.4.4 Rebuilding failed drives
You can manually rebuild failed hard disk drives using the
Rebuild
command in the
Management Menu
.
To rebuild a failed hard disk drive
1. From the
Management Menu
, select
Rebuild
, and then press <Enter>.
2. The
PHYSICAL DRIVES SELECTION MENU
displays the available drives
connected to the SATA ports. Select the drive you want to rebuild, and then
press <Space>.
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
Rebuild PD(s)
LSI Software RAID Conguration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
Port # 1 DISK 77247MB HDS728080PLA380 PF20A60A
REBUILD - PHYSICAL DRIVES SELECTION MENU
PORT #
ONLIN A00-00
FAIL A00-01
0
1
LSI Software RAID Conguration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
SPACE-(De)Select,F10-Start Rebuild,F2-Drive Information,F3-View Virtual Drives