Asus P7F-C Computer Hardware User Manual


 
5-38 Chapter 5: RAID configuration
8. When creating a
RAID 1
or a
RAID 10
set, select
DWC
from the
Virtual
Drive
menu, and then press <Enter>.
When creating a
RAID 0
set, proceed to step 10.
9. Select
On
to enable the
Disk Write Cache
setting, and then press <Enter>.
Enabling DWC can improve the performance, but with the risk of data loss.
10. When finished setting the selected virtual drive configuration, select
Accept
from the menu, and then press <Enter>.
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
PORT #
DNLIN A00-00
DNLIN A00-01
0
1
Easy Conguration - ARRAY SELECTION MENU
LSI Software RAID Conguration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
Virtual Drive(s) Congured
LD RAID Size #Stripes StripSz Status
0 1 77247MB 2 64 KB ONLINE
Virtual Drive 0
RAID = 1
Size = 77247MB
DWC = Off
RA = On
Accept
SPAN = NO
Disk Write Cache Setting Of VD
Change DWC
Off
On
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Congure Esc-Quit
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
PORT #
LSI Software RAID Conguration Utility Ver A.62 Apr 29, 2009
BIOS Version A.09.04300936R
DNLIN A00-00
DNLIN A00-01
0
1
Easy Conguration - ARRAY SELECTION MENU
Virtual Drive(s) Congured
LD RAID Size #Stripes StripSz Status
0 1 77247MB 2 64 KB ONLINE
Virtual Drive 0
RAID = 1
Size = 77247MB
DWC = Off
RA = On
Accept
SPAN = NO
Accept This VD Conguration And Go To Next VD
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Congure Esc-Quit