Asus TRL-DLS Network Card User Manual


 
ASUS TRL-DLS Users Manual58
4. BIOS SETUP
4. BIOS SETUP
Power Up Control
4.5.2 Hardware Monitor
MB Temperature [xxxC/xxxF]
CPU1 Temperature [xxxC/xxxF]
CPU2 Temperature [xxxC/xxxF]
The onboard hardware monitor is able to detect the MB (motherboard) and CPU
temperatures. Set to [Ignore] only if necessary.
CPU1 Fan Speed [xxxxRPM]
CPU2 Fan Speed [xxxxRPM]
SYSTEM Fan Speed [xxxxRPM]
The onboard hardware monitor is able to detect the CPU and system fan speeds in
rotations per minute (RPM). The presence of the fans is automatically detected.
VCORE1 Voltage, VCORE2 Voltage, 3.3V Voltage, 5V Voltage,
12V Voltage
, 3VSB Voltage
The onboard hardware monitor is able to detect the voltage output by the onboard
voltage regulators.
NOTE: If any of the monitored items is out of range, the following error
message appears: Hardware Monitor found an error. Enter Power setup
menu for details. You will then be prompted to Press F1 to continue or
DEL to enter SETUP.