ATEN Technology CS-64U Switch User Manual


 
Auto Scanning
The CS-64U’s Auto Scan feature automatically cycles the KVM
focus through the computer ports at regular intervals. This
allows you to monitor the computer activity without having to
take the trouble of switching from port to port manually. See the
table below for details.
Hotkey Action
[Scroll Lock] [Scroll
Lock] [A] [Enter]
Starts Auto Scan. The KVM focus cycles from
port to port at 5 second intervals.
[Scroll Lock] [Scroll
Lock] [A] [n] [Enter]
Starts Auto Scan. The KVM focus cycles from
port to port at n second intervals.
Note: 1. The n stands for the number of seconds that the
CS-64U should dwell on a port before moving on to
the next. Replace the n with a number between 1 and
99 when entering this hotkey combination.
2. While Auto Scan Mode is in effect, ordinary keyboard
and mouse functions are suspended - only Auto
Scan Mode compliant keystrokes and mouse clicks
can be input. You must exit Auto Scan Mode in order
to regain normal control of the console. To exit Auto
Scan Mode, press [esc] or [Spacebar].
- 9 -
2004-06-10