DLA2/4/6 Speaker Level Audio Router
Symptom Possible Cause Solution
Volume only ramps to 10 4 Ohm Speaker con-
nected to 8 Ohm-rated
ampliÀ er.
Normal operation. Func-
tions this way to protect
ampliÀ er.
IR Control
Symptom Possible Cause Solution
No source control in a
Room from IR port
1. Wiring: IR signal not
reaching Room input.
Check Room IR receiver
and verify wiring.
2. Remote Control bat-
teries are dead.
Replace batteries.
No source control in any
Room.
1. See above. Perform steps above.
2. Source IR Emitters
unplugged or defective.
Reconnect or test with
known good IR Emitters.
Intermittant source
control.
Mild to moderate IR
Flooding.
Check IR indicator on
front panel. If it Á ickers,
IR Á ooding is indicated.
Check any IR receivers
that may be receiving
ambiant light or plasma
TV noise.
Room appears to be on
and selected but unabled
to be controlled using
front panel buttons.
Extreme IR Á ooding.The
IR indicator will be solid
red when the room is off,
solid off when the room
is on, or solid purple
when the room is on and
unselected.
Perform steps above.