TMA; Reviewed:
SPOC 7/21/2008
Solution & Interoperability Test Lab Application Notes
©2008 Avaya Inc. All Rights Reserved.
16 of 21
ProCurve-ACM
4. Create and configure the data VLAN that will run between the control room and the closets.
• Assign a VLAN ID for the data VLAN.
• Assign a name for the data VLAN.
• Assign ports to the data VLAN.
ProCurve Switch 2626-PWR# configure
ProCurve Switch 2626-PWR(config)# vlan 30
ProCurve Switch 2626-PWR (vlan-30)# vlan 30 name Datavlan1
ProCurve Switch 2626-PWR (vlan-30)# tagged 1-2
ProCurve Switch 2626-PWR (vlan-30)# exit
5. Save the running configuration to the startup configuration.
ProCurve Switch 2626-PWR# configure
ProCurve Switch 2626-PWR(config)# write memory
8. Configure Closet-B ProCurve 2610-24-PWR Switch
This section addresses configuring the ProCurve 2610-24-PWR Switch. The ProCurve 2610-24-
PWR Switch is used as an edge switch to supply PoE power, support VLANs, link aggregation
and to enforce QoS policies.
To configure the ProCurve 2610-24-PWR Switch, connect a PC or laptop to the serial port of the
ProCurve 2610-24-PWR Switch. Run a terminal emulation program with the following
configuration:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None
1. Log into the ProCurve 2610-24-PWR Switch using the appropriate Login ID and Password.
Login:
Password:
ProCurve Switch 2610-24-PWR#