Avocent 3016 Switch User Manual


 
94 AutoView 3008/3016 Switch Installer/User Guide
Network Connection
Number 1
Type 10/100 Ethernet
Connector 8-pin modular
Local Port
Number 1
Type PS/2, USB and VGA
USB Device Port
Number 2
Type USB 1.1
Power Supply
Type Internal
Power 8.5 W
Heat Dissipation 29 BTU/hr
AC-input Range 100 - 240 VAC
AC Frequency 50 - 60 Hz autosensing
AC-input Current Rating 0.5 A
AC-input Power (maximum) 15 W
AC-input Cable
18 AWG three-wire cable, with a three-lead IEC-320; receptacle on the power
supply end and a country-dependent plug on the power resource end
Ambient Atmospheric Condition Ratings
Temperature
32 to 104 degrees Fahrenheit (0 to 40 degrees Celsius) operating;
-4 to 158 degrees Fahrenheit (-20 to 70 degrees Celsius) nonoperating
Humidity 10 - 95% noncondensing
Safety and EMC Standards
Approvals and Markings
UL, FCC, cUL, ICES-003, CE, VCCI, MIC, C-Tick, GOST
Safety certifications and EMC certifications for this product are obtained under
one or more of the following designations: CMN (Certification Model Number),
MPN (Manufacturer’s Part Number) or Sales Level Model designation. The
designation that is referenced in the EMC and/or safety reports and certificates
are printed on the label applied to this product.
Table D.1: AutoView 3008/3016 Switch Product Specifications (Continued)