Axis Communications 660 Printer User Manual


 
Management and Configuration AXIS 560/660 Users Guide
26
Using the Test Button
The following operations can be performed by pressing the test button in different
sequences. Please refer to Product Overview, on page 5, to identify the location of the
test button.
Printing a test page:
Press the test button once to print a test page.
Printing the parameter list:
Press the test button twice to print the parameter list.
Resetting the AXIS 560/660 parameters to the factory default settings:
1. Remove the external power supply to switch off the AXIS 560/660.
2. Press and hold down the test button, while you reconnect the external power
supply. Continue to hold down the test button until the network indicator starts
to flash at one second intervals. This should take about 5 seconds.
3. Release the test button and wait until the network indicator flashes at least five
times.
4. Press and hold down the test button again until the network indicator remains
constantly lit.
5. Restart the AXIS 560/660 by disconnecting and reconnecting the external power
supply.
Note:
Please refer to the AXIS 560/660 Users Manual for more information about the test
button.
All parameters except the node address (NODE_ADDR.), the IP address (IP_ADDR.) and DHCP
enabled or disabled (DHCP_ENABLE.) are reset.
NetWare
UNIX
Windows
OS/2