Baldor EXB013A01 Computer Hardware User Manual


 
6-12 Command Language
Table 6-1 Transaction Specification Table Continued
T# Name Type Data Field Class Description
51 SecurityLock Set INT or
NONE
All Unlocks or locks
network parameter
security. Passing the
valid SecurityCode
unlocks parameter
access. Any other
value (including
NONE) locks
parameter access.
52 CalcPresets Set BOOL E,S,V This transaction is
used during setup to
calculate initial
values for tuning and
performance
parameters based
on motor nameplate
values. Note: this
command is not valid
for all product
classes.
1 = Execute preset
calculation
0 = No action
56 BlockStructure Get USINT
Level1Max,
Level2Max,
Level3Max,
All Returns the number
of blocks on each
programming level.
Assumes a max of
three programming
levels.
57 BlockDetail Get C: USINT
Level, Block
R: USINT
MaxParams,
STRING
BlockName
All Returns the number
of parameters in the
block and the
BlockName (16
characters max.)
* Indicates initial powerup value.