Baldor EXB013A01 Computer Hardware User Manual


 
6-20 Command Language
36 or 37 - Optionald#
Command
36
Response
36 ST USINT Optionld
Type: Get
This transaction returns the id number for the option installed in
the specified location.
Table 6-4 provides a description of the possible values.
Table 6-4 Optionald# Table
ID EXB No. EXB Name Group
1 EXB001A01 RS232 Serial Communications 2
2 EXB002A01 RS422/485 Serial Communications 2
3 EXB003A01 Isolated Input 1
4 EXB004A01 4 Output Relays / 3-15 PSI Pneumatic 2
5 EXB005A01 Master Pulse Reference/Isolated Pulse
Follower
1
6 EXB006A01 DC Tachometer 1
7 EXB007A01 High Resolution Analog I/O 2
8 EXB008A01 Isolated Encoder 1
9 EXB009A01 Resolver to Digital 1
10 EXB010A01 2 Isolated Analog Output / 3 Relay 2
11 EXB012A00 RS232/485 Serial Communications 2