BaracodaPencil2 – Programming Guide v1.7 - 6 -
Data Capture
for Workforce
in Motion
By default, timers value are:
- when connected timer = 20 minutes
- Not connected timer = 10 minutes
Set shutdown timers to defaults
1.3.3/ No data loss mode and Baracoda Header
Baracoda header: It is a proprietary data encapsulation. It is necessary to activate it to use the Baracoda
keyboard emulation (Kemul) and Hyper terminal. The Baracoda header is enabled in default settings
No data loss mode: Baracoda has developed a proprietary communication protocol in order to enhance the
security of the Bluetooth transmission. Every barcode sent to the host must be acknowledged by the host (until
then, the scanner will transmit it again and again). This acknowledgment is disabled in default settings. It is
strongly recommended to set this protocol acknowledgment on when using the scanner with the
BaracodaManager.
Enable Baracoda header + “No Data loss mode” ON
Disable Baracoda header + “No data loss mode” OFF
Enable Baracoda header + “No Data loss mode” OFF (*)
1.3.4/ Timestamp Option
Time stamp can be configured (ON/OFF, set new date and new time) by the following configuration barcodes
Timestamp on
Timestamp off (*)