SYSMGR
Description: System Manager Settings
Parameters:
--blkinv (Black Invalid Mode) : 0=OFF, 1=ON
--vfd (VFD Brightness) : 0..6
--opmode (Operation Mode) : 0=SingleChannel, 1=DualChannel,
2=3DProcessing
Note: For the new operating take full effect, you must save settings and reboot the
unit.
--conmode (Encore Connect Mode)
: 0=OFF, 1=ON
--unitid (Encore Unit ID)
: 1..32
--encoreip (Encore IP address) : xxx.xxx.xxx.xxx
Query Format: SYSMGR --?
Query Response: System Manager Settings in the following format
SYSMGR --blkinv (Black Invalid Mode) --vfd (VFD Brightness) --opmode
(Operation Mode) --conmode (Encore Connect Mode) --unitid (Encore Unit ID)
--encoreip (Encore IP Address)
UINPUT
Description: Input Settings
Required parameters:
--con (connector)
--itype (input type), for commands to DVI input settings
Parameters:
--con (connector) : [0..5], see below for connector numbers.
--itype (input type) : 0 = digital, 1 = analog
--deint (deinterlacing type) : 0 = MotionAdaptive, 1 = FieldToFrame
--motion (motion threshold) : [0..15]
Examples:
UINPUT --con 0 --itype 0 --deint 0
(Update DVI (digital in) input, deinterlacing type to Motion Adaptive
Query Format: UINPUT --con (connector) --?
Query Response: Input Settings in the following format
UINPUT --deint (deinterlacing type) --motion (motion threshold)
Connectors:
0=DVI
1=HD15
2=HDMI
3=DP
4=SDI1
5=SDI2 (available when Dual option mezzanine installed)