Connections
3-3
5975688 BARCOVISION 1609S 131097
Connecting a Composite Video source to port 1.
Composite video signals from a VCR, OFF air signal decoder, etc..
Video input selection :
with the RCU or the build in RCU : press digit button 1
* Note : if using the loop-through Video output, then set the
Termination Switch to the "OFF" position.
Connecting a S-Video or Video source to port 2.
Separate Y-luma/C-chroma signals for higher quality playback of Super VHS signals.
Highlight Port 2 : Video and press ENTER to toggle between VIDEO
or S-VIDEO.
Press EXIT to return.
Press ADJUST to return to operational mode.
Select with or
then <ENTER>
<EXIT> to return.
ADJUSTMENT MODE
Select a path from below :
GUIDED
RANDOM ACCESS
INSTALLATION
SERVICE
IRIS
Source 02
Select with or
then <ENTER>
<EXIT> to return.
Choose a setup pattern
from below :
SELECTED SOURCE
GENLOCKED PATTERN
INTERNAL # PATTERN
Source 02
Select with or
then <ENTER>
<EXIT> to return.
RANDOM ACCESS
ADJUSTMENT MODE
PICTURE TUNING
GEOMETRY
CONVERGENCE
FOCUSING
COLOR SELECT
ORBITING
CONTR. MODULATION
SOFT EDGE
Select with or
<ENTER> to accept
<EXIT> to return.
PICTURE TUNING
COLOR BALANCE
SYNC : FAST
PORT2 : S-VIDEO
LINE DOUBLER : ON
Highlight 'Picture Tuning' and press ENTER.
Select 'Selected source' and press ENTER.
Input selection
with the RCU or the build in RCU : press digit button 2
Depending on the priority setting in the Picture Tuning menu,
Video or S-Video can be displayed.
If the setting is not correct, start up the adjustment mode by
pushing on th ADJUST key.
Select 'Random Access' and press ENTER.
* Note: When using the Port 2 loop-through output, set the Termination
Switch in the "OFF" position.
1
2
3
4
4 pin connector configurations:
For S-video:
Pin 1: earth(ground) luminance
Pin 2: earth(ground) chrominance
Pin 3: luminance signal(Y)
1Vpp ±3dB
Pin 4: chrominance signal(C)
300mVpp ±3dB
For video:
Pin 1: earth(ground) video
Pin 2: not connected
Pin 3: video signal
Pin 4: not connected