Barco RS232 Projector User Manual


 
2. Basic Commands
Command
Command [0]
\x27
Command [1]
\x01
Returned Data
Data [0] = Maximum contrast value
Example
Reads the Maximum contrast value of the projector, the awnser being \x64
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x27
Command[1]
\x01
Checksum
\x29
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x27
Command[1]
\x01
Data [0]
\x64
Checksum
\x8d
Stop
\xff
2.7.7 Brightness, increment
Description
Increments the Brightness by one.
Command
Command [0]
\x22
Command [1]
\x02
R5976884 RLM SERIES 04/04/2006 25