Barco RS232 Projector User Manual


 
2. Basic Commands
Receive (acknowledge)
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x45
Data [0]
\x00
Checksum
\x67
Stop
\xff
2.33 Standby Timer, Write
Description
Adjusts the Standby Timer in a range from 180 to 3600.
Command
Command [0]
\x20
Command [1]
\x98
Data
Unsigned word representing the standby time value:
Data[0] = msb
Data[1] = lsb
range: 180 to 3600 seconds
0 seconds = Standby timer OFF
Example
Sets the standby time to “400”
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x20
Command[1]
\x98
Data[0]
\x01
Data[1]
\x90
Checksum
\x4a
Stop
\xff
72 R5976884 RLM SERIES 04/04/2006