Barco RS232 Projector User Manual


 
2. Basic Commands
Returned Data
Data [0] = minimum Saturation value
Example
Reads the minimum Saturation value of the projector, the awnser being \x00
Transmit
Start
\xfe
Projector address
\x01
Command[0]
\x26
Command[1]
\x03
Checksum
\x30
Stop
\xff
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x26
Command[1]
\x03
Data [0]
\x00
Checksum
\x30
Stop
\xff
2.7.18 Maximum Saturation, Read
Description
Reads the Maximum (range) Saturation value of the projector
Command
Command [0]
\x27
Command [1]
\x03
Returned Data
Data [
0] = Maximum Saturation value
Examp
le
Reads the Maximum Saturation value of the projector, the awnser being \x7f
32
R5976884 RLM SERIES 04/04/2006