Belkin DLA-HD2KU Projector User Manual


 
1-8 (No.PA019)
2.2 LAMP UNIT INSTRUCTIONS
Refer to the OPERATING INSTRUCTIONS for a detailed oper-
ating description.
2.2.1 Lamp life
Life of the projector lamp (time to reach 1/2 average brightness)
is about 2000 hours.
Lamp use time can be checked at the menu < Information > -
[Lamp time].
2.2.2 Operation when lamp use time exceeds 1900 hours
z 1900 to 2000 HOURS
Power on : LAMP LED lights.
Operation : "Lamp replacement" message appears on
screen (press any button to extinguish).
z 2000 to 2010 HOURS
Power on : LAMP LED flashes.
Operation : "Warning" and "Lamp replacement" messages
appear on screen, and "Warning" flashes.
Press [EXIT] button to extinguish the display. But after 1
hour, "Warning" and "Lamp replacement" again appear.
NOTE:
At power off, the stand-by mode is produced and further op-
eration is prevented.
To again use the projector, replace the lamp unit and reset
the lamp use time indication.
z AFTER 2010 HOURS
Power on : Power is cut and cool-down mode entered,
LAMP and OPERATE LEDs flash.
2.2.3 Handling cautions
Use a cross-head screwdriver to take out and reinstall the lamp
cover (2 screws) and lamp unit (2 screws). Refer to the OPER-
ATING INSTRUCTIONS.
Observe the following cautions.
- Be sure to disconnect the power cord from the AC power
source.
- The lamp remains quite hot after power off. Be sure to allow
plenty of time (30 minutes to 1 hour) to cool before proceed-
ing.
- The lamp can break if dropped or subjected to physical
shock.
- Use care not to directly touch or soil the lamp projecting
(glass) face.
When installing the lamp unit, observe the interior projections
of the lamp cover are securely inserted into the holes of the
projector. Since the lamp cover projections engage the inter-
lock switch part of the protector circuit (normal operating state),
be sure the cover is properly positioned and secure with
screws.
The replaced old lamp (depleted lamp unit) can be discarded
in the same manner as a fluorescent lamp. Check local ordi-
nances and dispose of the used lamp as prescribed.
2.2.4 Lamp use time reset
Be sure to reset the Lamp use time after replacing the lamp
unit. Unless reset, the projector will cease operation (lamp will
not light) when 2000 hours are reached.
Conversely, reset the use time only after replacing the lamp.
RESETTING
(1) Set for stand-by mode.
(2) In sequence, press the [EXIT], [HIDE] and [PRESET]
buttons.
(3) Press the [] button for more than 2 seconds.
The STAND-BY and OPERATE LEDs alternately flash
for about 3 seconds, then only the STAND-BY LED
lights steadily.
RESET AFTER REPLACING MAIN PWB ASS'Y
The lamp use time data are stored in memory on the MAIN
PWB ASS'Y and need to be reentered after replacing the
MAIN PWB ASS'Y. Use the special software and a personal
computer to reenter the data. Afterwards, confirm the mode
has been returned to that prior to board replacement.
LAMP UNIT : BHL5006-S