BenQ W5000 Projector User Manual


 
44
Additional information
English
Timing of replacing the lamp
When the Lamp indicator lights up red or a message appears suggesting it is time to replace the lamp, please
install a new lamp or consult your dealer. An old lamp may cause a malfunction in the projector and in some
instances the lamp may explode.
The Lamp indicator light and Temperature warning light will light up if the lamp becomes too hot. Turn the
power off and let the projector cool for 45 minutes. If the Lamp or Temp indicator still lights up after turning the
power back on, please contact your dealer. See "Indicators" on page 47 for details.
The following Lamp warning displays will remind you to change the lamp.
Replacing the lamp
To reduce the risk of electrical shock, always turn the projector off and disconnect the power cord before
changing the lamp.
To reduce the risk of severe burns, allow the projector to cool for at least 45 minutes before replacing the
lamp.
To reduce the risk of injuries to fingers and damage to internal components, use caution when removing
lamp glass that has shattered into sharp pieces.
To reduce the risk of injuries to fingers and/or compromising image quality by touching the lens, do not
touch the empty lamp compartment when the lamp is removed.
This lamp contains mercury. Consult your local hazardous waste regulations to dispose of this lamp in a
proper manner.
Status Message
The lamp has been in operation for 2000 hours. Install a new lamp for
optimal performance. If the projector is normally run with Whisper selected
(See "Getting to know the lamp hour" on page 43), you may continue to
operate the projector until the 2950 hour lamp warning appears.
Press ENTER to dismiss the message.
The lamp has been in operation for 2980 hours. It is strongly recommended
that you replace the lamp at this age. The lamp is a consumable item. The
lamp brightness diminishes with use. This is normal lamp behavior. You can
replace the lamp whenever you notice that the brightness level has
significantly diminished. If the lamp is not replaced beforehand, it should be
replaced after 2950 hours usage.
Press ENTER to dismiss the message.
The lamp has been in operation for 3000 hours. The lamp MUST be replaced
before the projector will operate normally.
Press ENTER to dismiss the message.
OK
NOTICE: Order replacement lamp
Lamp > 2000hrs
WARNING
OK
NOTICE: Order replacement lamp
Lamp > 2980hrs
WARNING
NOTICE: Replace lamp now
Lamp > 3000hrs
Lamp-usage time exceeded
Replace lamp (refer to User Manual)
then reset lamp timer
OK
WARNING
W20000-en.book Page 44 Monday, October 22, 2007 3:35 PM