Black Box LBH240A Network Hardware User Manual


 
Black Box
®
Heavy Duty Edge Switches Installation and User Guide(07/05)
53
3.8.5 Power Budget Calculations
for Heavy-Duty LBHXXX, Fiber Media
Receiver Sensitivity and Transmitter Power are the parameters necessary to
compute the power budget. To calculate the power budget of different fiber media
installations using Black Box products, the following equations should be used:
OPB (Optical Power Budget) = P
T
(min) - P
R
(min)
where P
T
= Transmitter Output Power, and P
R
= Receiver Sensitivity
Worst case OPB = OPB - 1dB(for LED aging) - 1dB(for insertion loss)
Worst case distance = {Worst case OPB, in dB} / [Cable Loss, in dB/Km]
where the “Cable Loss” for 62.5/125 and 50/125
µm (m.m.) is 2.8 dB/km,
and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km,
and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km
and the “Cable Loss” for 9/125 (Single-mode) is 0.25 dB/km (SSCX)
The following data has been collected from component manufacturer’s (Agilent’s, JDS-
Uniphase, stratus, Lucents’) web sites and catalogs to provide guidance to network
integrators and installers-