Black Box LES1416A Server User Manual


 
To change the timezone:
# config -s config.system.timezone=US/Eastern
The following command will synchronize the live system with the new configuration:
# config -r time
14.20 Dial-in settings
To enable dial-in access on the DB9 serial port from the command line with the following attributes:
Local IP Address 172.24.1.1
Remote IP Address 172.24.1.2
Authentication Type: MSCHAPv2
Serial Port Baud Rate: 115200
Serial Port Flow Control: Hardware
Custom Modem Initialization: ATQ0V1H0
Callback phone 0800223665
User to dial as user1
Password for user secret
Run the following commands:
# config -s config.console.ppp.localip=172.24.1.1
# config -s config.console.ppp.remoteip=172.24.1.2
# config -s config.console.ppp.auth=MSCHAPv2
# config -s config.console.speed=115200
# config -s config.console.flow=Hardware
# config -s config.console.initstring=ATQ0V1H0
# config -s config.console.ppp.enabled=on
# config -s config.console.ppp.callback.enabled=on
# config -s config.console.ppp.callback.phone1=0800223665
# config -s config.console.ppp.username=user1
# config -s config.console.ppp.password=secret
To make the dialed connection the default route:
# config -s config.console.ppp.defaultroute=on
Please note that supported authentication types are 'None', 'PAP', 'CHAP' and 'MSCHAPv2'.
Supported serial port baud-rates are '9600', '19200', '38400', '57600', '115200', and '230400'.
Supported parity values are 'None', 'Odd', 'Even', 'Mark' and 'Space'.
Supported data-bits values are '8', '7', '6' and '5'.
Supported stop-bits values are '1', '1.5' and '2'.
Supported flow-control values are 'Hardware', 'Software' and 'None'.
If you do not want to use out-of-band dial-in access, note that the procedure for enabling start-up
messages on the console port is covered in Chapter 15—Accessing the Console Port.
The following command will synchronize the live system with the new configuration:
# config -a
14.21 DHCP server
To enable the DHCP server on the console management LAN, with settings:
Default lease time 200000 seconds
Maximum lease time 300000 seconds
_____________________________________________________________________
724-746-5500 | blackbox.com Page 233