TM
SLE100 Installation Manual
30 590-00532, rev A
4 Configuring Network Equipment
The networking equipment that is connected to the SLE100 should first be checked to ensure it
operates properly over a wired connection.
We recommend the network equipment on both sides of the link be configured as follows:
• Port auto-negotiation turned on
• Port configured to not enter error-disable state due to multiple link up/down
transitions (since these may occur during periods of heavy rainfall)
The radio’s 10/100Base-T port is permanently set to auto-
negotiate.
4.1 Network Port Statistics
Verify, if possible, the following on the user’s network equipment (connected to the radios), in
addition to verifying these values using the radio’s Network Management System:
• Link integrity
• There are no receive errors on the link
• Network traffic is flowing in both directions.
The radios support all standard Ethernet frame sizes, up to 1632
bytes for un-tagged or 802.1q VLAN-tagged frames.