BridgeWave SLE100 Network Card User Manual


 
TM
SLE100 Installation Manual
30 590-00532, rev A
4 Configuring Network Equipment
The networking equipment that is connected to the SLE100 should first be checked to ensure it
operates properly over a wired connection.
We recommend the network equipment on both sides of the link be configured as follows:
Port auto-negotiation turned on
Port configured to not enter error-disable state due to multiple link up/down
transitions (since these may occur during periods of heavy rainfall)
The radio’s 10/100Base-T port is permanently set to auto-
negotiate.
4.1 Network Port Statistics
Verify, if possible, the following on the user’s network equipment (connected to the radios), in
addition to verifying these values using the radio’s Network Management System:
Link integrity
There are no receive errors on the link
Network traffic is flowing in both directions.
The radios support all standard Ethernet frame sizes, up to 1632
bytes for un-tagged or 802.1q VLAN-tagged frames.