Brother FAX-931 Fax Machine User Manual


 
V - 31
WSW18 (Function setting 3)
Selector
No.
Function Setting and Specifications
1 Not used.
2
3
Detection enabled time for CNG
and no tone
No. 2 3
0 0 : 40 sec.
0 1 : 0 sec. (No detection)
1 0 : 5 sec.
1 1 : 80 sec.
4
5
Not used.
6 Registration of station ID 0: Permitted 1: Prohibited
7
8
Tone sound monitoring
No. 7 8
0 X : No monitoring
1 0 : Up to phase B at the
calling station only
1 1 : All transmission phases
both at the calling and
called stations
l Selectors 2 and 3: Detection enabled time for CNG and no tone
After the line is connected via the external telephone or by picking up the handset of the facsimile
equipment, the equipment can detect a CNG signal or no tone for the time length specified by these
selectors. The setting specified by these selectors becomes effective only when selector 8 of
WSW20 is set to "1."
l Selector 6: Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and Czech versions.
l Selectors 7 and 8: Tone sound monitoring
These selectors set monitoring specifications of the tone sound inputted from the line.