Cabletron Systems MICROMMAC- Switch User Manual


 
TROUBLESHOOTING
5-3
5.2.1 Static System Messages
Static System messages (Table 5-2) display MicroMMAC-T configuration
information. To view them, press and release the Display button
(Figure 5-1). Press the Display button to scroll through each message. If
the Display button is not pressed again within ten seconds, the display
defaults back to the product name.
Table 5-2. Static System Messages
Displayed Message Significance
IP Address
xxx.xxx.xxx.xxx
Displays current IP address. This can be changed via
Local Management
MAC Address
xx.xx.xx.xx.xx.xx
Displays Hardware or MAC address
RAM Image
Rev. xx.xx.xx
Displays currently executing image
Boot PROM
Rev. xx.xx.xx
Displays internal Boot PROM version number
Flash Programmed
xx Times
Displays number of times Flash EEPROM has been
programmed.
COM 1
Baud Rate xxxxxx
Displays COM 1 Port’s current Baud rate
COM 1
Function xxxxxx
Displays COM 1 Port’s current function (Local
Management console, UPS, or SLIP)
COM 2
Baud Rate xxxxxx
Displays COM 2 Port’s current Baud rate
COM 2
Function xxxxxx
Displays COM 1 Port’s current function