Cabletron Systems TM 9C300-1 Network Card User Manual


 
3-9
Non-Interactive Mode
Non-Interactive Mode
The LCD defaults to this mode if there is no user input within 60 seconds of
installation of the Environmental Module or system start-up.
Non-Interactive Mode Screens
This section describes the LCD screens that display in the non-interactive mode.
The LCD scrolls through different status screens (depending on MMAC-Plus
configuration), displaying each screen for a period of 7 seconds; or, until user
input is sensed on the keypad.
Line 4 of each screen displays any active alarm conditions that exist within the
system. If no alarm conditions exist, the line displays “SYSTEM STATUS
NORMAL.”
If an alarm condition exists, line 4 displays a message describing the alarm for 5
seconds. The screen then displays a message stating how many alarms are present
in the alarm queue, “XX ALARMS PENDING” and the ALARM LED on the front
of the Environmental Module turns yellow or red indicating unread alarms in the
queue.
The System Screen
The System Screen, as shown in Figure 3-7, is the first screen of the
non-interactive mode.
Lines 1 and 2 display the MMAC-Plus chassis Internet Protocol (IP) address and
Media Access Control (MAC) address.
Line 3 displays the current chassis hardware revision and serial number.
Line 4 displays the system status.
Figure 3-7. The System Screen
CHASSIS IP ADDRESS xxx.xxx.xxx.xxx
CHASSIS MAC ADDRESS xx-xx-xx-xx-xx-xx
CHASSIS HW REV xxx SN xxxxxxxxxxxx
SYSTEM STATUS NORMAL