Casio WK-3200 Personal Computer User Manual


 
64
37 SMF Parameter Set
System Exclusive Format
Data Format
Bulk dumping SMF data transfers the data with a 128-byte header appended as shown below. The header data starts with
an 8-byte file name, which is displayed by this Model after receipt.
Field Value
01 SYSEX F0
02 MAN 44
03 MOD 11,02
04 dev Either 00 to 1F, or 7F
05 act 04(HDS), 05(HDR), 07(Control)
06 cat SMF = 10
07 prm 00-7F
08 ilen/dlen See "IV This Model's System Exclusive Messages".
09 ps Indicates the SMF number being transferred.
For details, see "39 About Parameter Set (PS) numbers".
10 index See "IV This Model's System Exclusive Messages".
11 data See "IV This Model's System Exclusive Messages".
12 sum See "IV This Model's System Exclusive Messages".
13 EOX F7
Header 128Bytes Name 8Bytes
Reserved 120Bytes
SMF Data