Chief Manufacturing RSM A-D Projector Accessories User Manual


 
RSM Elite Series Projector Mounts Installation Instructions
8
1b
Ø 6.3mm
(Ø 1/4”)
64mm
(2-1/2”)
Concrete Installation
1. Determine mounting location.
WARNING: The RSM is designed to be mounted to a
concrete ceiling with a minimum thickness of 8" and a
maximum drywall covering of 5/8".
WARNING: IMPROPER INSTALLATION CAN
RESULT IN SERIOUS PERSONAL INJURY OR
DAMAGE TO EQUIPMENT! Structural members MUST
be capable of supporting five times the combined weight
of all equipment being mounted.
2. Using the RSM as a guide, mark four mounting hole
locations on ceiling using a pencil or similar tool.
3. Drill four 1/4" (6.3mm) dia. pilot holes to a depth of
2-1/2" (64mm) deep.
4. Align four mounting holes in RSM with four pilot holes.
IMPORTANT ! : Make sure mount is properly
oriented towards target before securing to structure.
WARNING: Anchors (not provided) must be installed
into structurally sound solid concrete. Installation into
hollow concrete block, mortar, or concrete that exhibits
cracking, spalling, or other defects may result in failure
of anchor and serious personal injury or damage to
equipment.
5. Install four 3/8" x 2-1/4" Grade 2 concrete anchors
(not included) by inserting into pilot holes and
pounding in until flush with mounting surface.
6. Secure RSM to structure using four #10 flat washers
and four #10 x 3" Phillips head wood screws (not
included).
(A)
3
x 4
x 4
1
2
5
x 4
6
x 4
4