FuzzyScan Fixed Mount
Scan
Programming Manual
45
PROGRAM
Operation Control
♦
♦♦
♦ Time-out and Duration Setting ♦
♦♦
♦
F_DEFAULT
Family Code Selection P.C
Parameter Selection Option Code
Scan Input Time-out
SS
SS
SS
SS
SS
MS
100 msec.
200 msec.
300 msec.
400 msec.
500 msec.
600 msec.
700 msec.
800 msec.
900 msec.
User define: 1-99 sec.
0
1
2
3
4
5
6
7
8
9, (2digits)
Hands Free Time-out
SS
SS
SS
SS
SS
Short
Medium
Long
Extremely long
Disable
0
1
2
3
4
Good Read Duration
SS
SS
SS
SS
SS
Short
Medium
Long
Extremely long
Extremely short
0
1
2
3
4
The Scan Input Time-out is a preset light source time out counter for Alternative Mode, Presentation Mode and Level Mode. The scanner keeps the light source on till the
preset light source on time is up. You can adjust this parameter to meet your own application requirement.
The presentation mode and force mode will be automatically changed to manual trigger mode when you activate the trigger. You can remain the scanner in manual trigger
mode by setting the Hands Free Time-Out. Once the time-out duration is up (if there’s no any trigger operation), the imager will revert to the original presentation or force
mode.