FuzzyScan
Programming Manual
Configure Your FuzzyScan
44
PROGRAM
Operation Control
♦
♦♦
♦ Presentation Scanning Setting , Trigger Control♦
♦♦
♦
F_DEFAULT
Family Code Selection P.C
Parameter Selection Option Code
SmartStand Power Off Timeout
SS
SS
SS
3 mins
5 mins
10 mins
Only available for FuuzzyScan Laser model
0
1
2
Presentation Auto-sense
SS
SS
Disable
Enable
0
1
Presentation Sensitivity
SS
SS
SS
SS
SS
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
0
1
2
3
4
5
6
Trigger Control
SS
SS
SS
Enable left trigger, disable right trigger
Enable right trigger, disable left trigger
Enable left and right triggers
Only available for FuzzyScan F460/F468
0
1
2
The SmartStand Power Off Timeout is a pre-defined duration for scanner’s light source on time when the scanner is placed on SmartStand. While the scanner is placed on
SmartStand, the scanner’s will be switched from hand-held scanning to presentation scanning and the light source will be forced on automatically. The light source will be
off when the pre-defined duration is up.
When enable the Presentation Auto-sense, the scanner can be switched between hands free scanning and hand-held scanning automatically when working with the
SmartStand.
The presentation sensitivity is used to configure the sensitivity level when the scanner is set as presentation mode. The higher lever means higher sensitivity for detecting
the barcode.