Cisco Systems 3600 Series Network Router User Manual


 
5
Installing the Grounding Lug on Cisco 2600 Series and Cisco 3600 Series Routers
78-11640-01
Installing the Grounding Lug on a Cisco 3620 or Cisco 3640 Router
Figure 3 Cisco 2600 Series Grounding Lug Installation
Installing the Grounding Lug on a Cisco 3620 or
Cisco 3640 Router
To attach the grounding lug to your router chassis, complete the following tasks:
Step 1 Turn OFF power to the router. However, to channel ESD voltages to ground, do not unplug the power
cable. Remove all network interface cables, including telephone cables, from the rear panel.
The following warning applies to routers that use a DC power supply:
Warning
Before performing any of the following procedures, ensure that power is removed from
the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel
board that services the DC circuit, switch the circuit breaker to the OFF position, and
tape the switch handle of the circuit breaker in the OFF position.
Step 2 Use a no. 2 Phillips screwdriver to remove either of the following:
1 mounting screw from the power supply on the right side of the Cisco 3620 router rear panel
2 mounting screws from the power supply on the right side of the Cisco 3640 router rear panel
Figure 4 and Figure 5 show Cisco 3620 DC and AC power supplies; Figure 6 and Figure 7 show
Cisco 3640 DC and AC power supplies. The DC and AC power supplies for these router models differ
in appearance, but the number and position of the mounting screws are the same for each platform.
36453
SEE MANUAL BEFORE INSTALLATION
SERIAL 1
SERIAL 0
CONN
CONN
WIC
2A/S
SEE MANUAL BEFORE INSTALLATION
SERIAL 1
SERIAL 0
CONN
CONN
WIC
2A/S
Cisco 2611
W0
AUX
CONSOLE
ETHERNET 0/0
ACT
LINKACTETHERNET 0/1LINK
Ethernet 0/0
10BASE-T
port (RJ-45)
Ethernet 0/1
10BASE-T
port (RJ-45)
Auxiliary
port (RJ-45)
Console
port (RJ-45)
Link
LED
ACT
LED
Link
LED
ACT
LED
G
rounding lug
Grounding cable