Cisco Systems ACIP-SM(=) Network Card User Manual


 
28 ATM Cable Interface Processor (ACIP) Installation and Configuration
Examples of ATM Error Messages
To display ATM events, use the debug atm events command:
This command displays event changes to the ACIP. Reset, VC configurations, ACIP
configurations, and PLIM failures are displayed.
After you use a debug command, turn off debugging with the no debug command.
Following are additional debug commands specifically related to the ACIP:
To display changes in connectivity to the TeraLink system, use the debug cable channel
command.
To display changes in subscriber modem status, use the debug cable modem command.
To display error messages that are caused by unexpected system behavior or problems
connecting to the Teralink system, use the debug cable error command.
Examples of ATM Error Messages
Following is a list of possible error messages displayed when you enter the debug atm event
command:
Error Message
RESET(ATM2/0): PLIM type is 0, Rate is 0Mbps
Explanation
Displays the PLIM TYPE value returned from the ACIP and the expected associated
rate.
Error Message
AIP_disable(ATM2/0): state=1
Explanation The DISABLE code to shut the ACIP down has been entered.
Error Message
config(ATM2/0)
Explanation The current configuration to the ACIP was sent including TXBUFF, RXBUFF,
exception queue length, raw queue length, and rate queue information.
Error Message
AIP_enable(ATM2/0)
Explanation The ACIP is taken out of shutdown.