Cisco Systems RPS 2300 Switch User Manual


 
12
Installation Notes for Catalyst 3750-E, Catalyst 3560-E Switches and RPS 2300 Power Supply Modules
78-17570-01
Technical Specifications
Step 4 Torque all terminal block screws to 5 lbf-in. (80 ozf-in.).
Step 5 Replace the terminal block plastic safety cover, and torque the screw to 10 lbf-in. (160 ozf-in.).
Step 6 Move the DC-power source circuit-breaker handles to the ON position.
Step 7 Confirm that the power supply DC OK LED is green. See Table 3 for a description of the module LEDs.
Technical Specifications
Table 4 Power Supply Module Environmental and Physical Specifications
Environmental Ranges
Operating temperature 23 to 113° F (–5 to 45° C)
Storage temperature –40 to 158° F (–40 to 70° C)
Relative humidity 10 to 95% (noncondensing)
Altitude Up to 10,000 ft (3049 m)
Physical Specifications
Weight C3K-PWR-1150WAC: 5.6 lb (2.6 kg)
C3K-PWR-750WAC: 3.9 lb (1.8 kg)
C3K-PWR-265WAC: 3.3 lb (1.5 kg)
C3K-PWR-265WDC: 3.5 lb (1.6 kg)
Physical Specifications
Dimensions (H x D x W) C3K-PWR-1150WAC:
1.65 x 14.90 x 6.0 in. (4.19 x 37.85 x 15.24 cm)
C3K-PWR-750WAC:
1.65 x 11.4 x 6.0 in. (4.19 x 28.96 x 15.24 cm)
C3K-PWR-265WAC:
1.65 x 11.4 x 6.0 in. (4.19 x 28.96 x 15.24 cm)
C3K-PWR-265WDC:
1.65 x 11.4 x 6.0 in. (4.19 x 28.96 x 15.24 cm)
Table 5 AC-Power Supply Module Power Specifications
Power Specifications
Maximum output power C3K-PWR-1150WAC: 1150 W
C3K-PWR-750WAC: 750 W
C3K-PWR-265WAC: 265 W
Input voltage range and frequency C3K-PWR-750WAC: 750 W, C3K-PWR-265WAC: 265 W:
100 to 240 VAC (autoranging), 47 to 63 Hz.
C3K-PWR-1150WAC: 1150 W:
115 to 240 VAC (autoranging) 47 to 63 Hz.