Citizen S4000L Printer User Manual


 
— 19 —
3.6 Setting DIP Switch
The DIP switch is present on the serial interface board.
The function of each switch is as shown below.
Baud Rate (bps)
Switch No. Function ON OFF
DIP switch
Interface board
mounting screws
CAUTION!
As for the setting of the serial interface, it gives priority to the setting of the memory
switch rather than the DIP switch as the factory default.
Consult with the dealer where the printer was purchased when the change of the DIP
switch setting is necessary.
Initial
Settings
1
Communication condition
DIP switch setting Memory switch OFF
setting method
setting
2 Hand shake XON/XOFF DTR/DSR OFF
3 Bit length 7 bits 8 bits OFF
4 Parity check With parity None OFF
5 Parity selection Even parity Odd parity OFF
6 OFF
7 ON
8 INIT Reset Invalid OFF
Selecting baud rate
Switch No.
67
2400 OFF OFF
4800 ON OFF
9600 OFF ON
19200 ON ON
38400, 57600 and 115200 bps can also be selected by a command, etc.
Baud rate selection See Table below.