Citizen Systems CT-S2000DC Printer User Manual


 
— 17 —
CAUTION!
DO NOT connect any other device than the specified cash drawer to the cash drawer
kick-out connector. (DO NOT connect a telephone line either.)
3.3 Connecting the Cash Drawer
Cash drawer
kick-out connector
Cash drawer cable connector
(1) Connector Pin Configuration
(2) Electrical characteristics
1) Driving voltage: 24 VDC
2) Driving current: Approx. 1A max. (shall not exceed 510 ms.)
3) DRSW signal: Signal levels: “L” = 0 to 0.5 V, “H” = 3 to 5 V
(3) DRSW signal
DRSW signal status can be tested with
the DLE+EOT, GS+a, or GS+r command or
at pin 34 on the parallel interface port.
(4) Drive Circuit (printer side)
No. Signal Function
1FG Frame Ground
2 DRAWER 1 Drawer 1 drive signal
3 DRSW Drawer switch input
4 VDR Drawer drive power supply
5 DRAWER 2 Drawer 2 drive signal
6 GND Common ground on circuits
61
Connector used:
TM5RJ3-66 (Hirose)
or equivalent
Applicable connector:
TM3P-66P (Hirose) or
equivalent
CAUTION!
No output is produced while printing.
The cash drawers 1 and 2 cannot be driven simultaneously.
A solenoid used for the cash drawer should be of 24 or more. The output current
should be kept at 1A or less; otherwise, breakdown or burning could occur.
VDR
1
2
3
4
5
6
VDR
5V
1. Confirm that the power switch is OFF.
2. Confirm the top and bottom of the cash
drawer cable connector and insert it into
the cash drawer kick-out connector at the
back of the printer.
3. Screw the cash drawer's ground wire to the
body of the printer.