iDP-3540/41 User’s Manual
CITIZEN 42/48
12-2-22. First Drawer Drive Command
D8 D1
0 0 0 0 0 1 1 1
BEL (07) H
This command generates a drive pulse for first drawer based on the condition of drive pulse
duration setting command.
This command is stored in the buffer and is performed when it is received from buffered queue.
12-2-23. First Drawer Quick Drive Command
D8 D1
0 0 0 1 1 1 0 0
FS(1C) H
This command generates a drive pulse for first drawer based on the condition of drive pulse
duration setting command.
This command is performed when the printer receiver it.
12-2-24. Second Drawer Derive Command
D8 D1
0 0 0 1 1 1 0 0
SUB (1A) H
This command generates a drive pulse for second drawer. And drive pulse duration is fixed at
200 ms ON + 200 ms OFF.
This command is performed when printer receive it.
Remarks: First drawer and second drawer cannot be driven at the same time.